2020 ISMRM and SMRT Virtual Conference and Exhibition
8 August 2020 – 14 August 2020 · Online, Virtual
0154 ISMRM Abstract

Eliminating chemical shift and relaxation effects in QSM using SMURF imaging

Accepted
Beata Bachrata 1,2,3, Bernhard Strasser1,2,4, Wolfgang Bogner1,2, Albrecht I Schmid1,5, Siegfried Trattnig1,2,3, Simon D Robinson1,2,6,7
1High Field MR Centre, Medical University of Vienna, Vienna, Wien, Austria
2Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Wien, Austria
3Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
4Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, United States of America
5Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Wien, Austria
6Centre for Advanced Imaging, The University of Queensland, Brisbane, QLD, Australia
7Department of Neurology, Medical University of Graz, Graz, Austria
Presenting Author: Beata Bachrata
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here.

This content is freely available and no longer restricted to registered attendees. Log in or create a free account to view it.

Log in

References

1. Wei H, Dibb R, Decker K, et al. Investigating magnetic susceptibility of human knee joint at 7 tesla. Magn Reson Med.
2. Straub S, Laun FB, Emmerich J, et al. Potential of quantitative susceptibility mapping for detection of prostatic calcifications. J Magn Reson Imaging JMRI. 2017;45(3):889-898. doi:10.1002/jmri.25385 Ren J, Dimitrov I, Sherry AD, Malloy CR. Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 Tesla. J Lipid Res. 2008;49(9):2055-2062. doi:10.1194/jlr.D800010-JLR200 Yu H, McKenzie CA, Shimakawa A, et al. Multiecho reconstruction for simultaneous water-fat decomposition and T2* estimation. J Magn Reson Imaging. 2007;26(4):1153-1161. doi:10.1002/jmri.21090 Bachrata B, Strasser B, Schmid AI, Bogner W, Trattnig S, Robinson SD. Eliminating chemical shift artefact using simultaneous, separate water and fat excitation combined with CAIPIRINHA. In: Proceedings of the 27th Annual Meeting of ISMRM. Montreal, Quebec, Canada, 2019. p. [doi]
3. Sharma SD, Fischer R, Schoennagel BP, et al. MRI-based quantitative susceptibility mapping (QSM) and R2* mapping of liver iron overload: Comparison with SQUID-based biomagnetic liver susceptometry: QSM and R2*: Comparison With SQUID. Magn Reson Med. 2017;78(1):264-270. doi:10.1002/mrm.26358 Schweser F, Herrmann K-H, Deistung A, et al. Quantitative magnetic susceptibility mapping ( QSM ) in breast disease reveals additional information for MR-based characterization of carcinoma and calcification. In: Proceedings of the 19th Annual Meeting of ISMRM. Montreal, Quebec, Canada, 2011. p. [doi]
4. Müller S. Multifrequency selective rf pulses for multislice MR imaging. Magn Reson Med. 1988;6(3):364-371. Breuer FA, Blaimer M, Heidemann RM, Mueller MF, Griswold MA, Jakob PM. Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging. Magn Reson Med. 2005;53(3):684-691. doi:10.1002/mrm.20401 Setsompop K, Gagoski BA, Polimeni JR, Witzel T, Wedeen VJ, Wald LL. Blipped-Controlled Aliasing in Parallel Imaging (blipped-CAIPI) for simultaneous multi-slice EPI with reduced g-factor penalty. Magn Reson Med. 2012;67(5):1210-1224. doi:10.1002/mrm.23097 Pruessmann K, Weiger M, Scheidegger M, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999;42(5):952-962. Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47(6):1202-1210. Eckstein K, Dymerska B, Bachrata B, et al. Computationally Efficient Combination of Multi-channel Phase Data From Multi-echo Acquisitions (ASPIRE): Combination of Multi-Channel Phase Data from Multi-Echo Acquisitions (ASPIRE). Magn Reson Med. 2018;79(6):2996-3006. doi:10.1002/mrm.26963 Schofield MA, Zhu Y. Fast phase unwrapping algorithm for interferometric applications. Opt Lett. 2003;28(14):1194-1196. Liu T, Khalidov I, de Rochefort L, et al. A novel background field removal method for MRI using projection onto dipole fields (PDF). NMR Biomed. 2011;24(9):1129-1136. doi:10.1002/nbm.1670 Li W, Wang N, Yu F, et al. A method for estimating and removing streaking artifacts in quantitative susceptibility mapping. NeuroImage. 2015;108:111-122. doi:10.1016/j.neuroimage.2014.12.043 Chan K-S, Marques J. SEPIA - SuscEptibility mapping PIpeline tool for phAse images. In: Proceedings of the 27th Annual Meeting of ISMRM. Montreal, Quebec, Canada, 2019. p. 4827. [doi]

Cite this abstract