Simultaneous Multiple Resonance Frequency (SMURF) imaging: Fat-water imaging using multi-band principles

Accepted
Beata Bachrata 1,2,3, Bernhard Strasser1,2,4, Wolfgang Bogner1,2, Albrecht I Schmid1,5, Siegfried Trattnig1,2,3, Simon D Robinson1,2,6,7
1High Field MR Centre, Medical University of Vienna, Vienna, Wien, Austria
2Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Wien, Austria
3Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
4Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, United States of America
5Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Wien, Austria
6Centre for Advanced Imaging, The University of Queensland, Brisbane, QLD, Australia
7Department of Neurology, Medical University of Graz, Graz, Austria
Presenting Author: Beata Bachrata
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here.

This content is freely available and no longer restricted to registered attendees. Log in or create a free account to view it.

Log in

References

1. Müller S. Multifrequency selective rf pulses for multislice MR imaging. Magn Reson Med. 1988;6(3):364-371. Breuer FA, Blaimer M, Heidemann RM, Mueller MF, Griswold MA, Jakob PM. Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging. Magn Reson Med. 2005;53(3):684-691. doi:10.1002/mrm.20401 Setsompop K, Gagoski BA, Polimeni JR, Witzel T, Wedeen VJ, Wald LL. Blipped-Controlled Aliasing in Parallel Imaging (blipped-CAIPI) for simultaneous multi-slice EPI with reduced g-factor penalty. Magn Reson Med. 2012;67(5):1210-1224. doi:10.1002/mrm.23097 Pruessmann K, Weiger M, Scheidegger M, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999;42(5):952-962. Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47(6):1202-1210. Yu H, Reeder SB, Shimakawa A, Gold GE, Pelc NJ, Brittain JH. Implementation and Noise Analysis of Chemical Shift Correction for Fast Spin Echo Dixon Imaging. In: Proceedings of the 12th Annual Meeting of ISMRM. Kyoto, Japan, 2004. p. 2686; :1. Jezzard P, Balaban RS. Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med. 1995;34(1):65-73. Optimization of chemical shift selective suppression of fat - Kuroda - 1998 - Magnetic Resonance in Medicine - Wiley Online Library. https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.1910400402. Accessed June 9, 2019. Rofsky NM, Lee VS, Laub G, et al. Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology. 1999;212(3):876-884. doi:10.1148/radiology.212.3.r99se34876 Hernando D, Kellman P, Haldar JP, Liang Z-P. Robust Water/Fat Separation in the Presence of Large Field Inhomogeneities Using a Graph Cut Algorithm. Magn Reson Med. 2010;63(1):79-90. doi:10.1002/mrm.22177 ISMRM Fat-water toolbox. ISMRM fat-water separation workshop 2012. “http://www.ismrm.org/workshops/FatWater12/.” Shinnar M, Eleff S, Subramanian H, Leigh JS. The synthesis of pulse sequences yielding arbitrary magnetization vectors. Magn Reson Med. 1989;12(1):74-80. Le Roux P. Exact synthesis of radio frequency waveforms. January 1988. Conolly S, Nishimura D, Macovski A. Optimal Control Solutions to the Magnetic Resonance Selective Excitation Problem. IEEE Trans Med Imaging. 1986;5(2):106-115. doi:10.1109/TMI.1986.4307754 Hargreaves BA, Cunningham CH, Nishimura DG, Conolly SM. Variable-rate selective excitation for rapid MRI sequences. Magn Reson Med. 2004;52(3):590-597. doi:10.1002/mrm.20168 Yang C, Deng W, Stenger VA. Simple Analytical Dual-Band Spectral-Spatial RF Pulses for B1+ and Susceptibility Artifact Reduction in Gradient Echo MRI. Magn Reson Med. 2011;65(2):370-376. doi:10.1002/mrm.22725 [doi]

Cite this abstract