365-03-001 ISMRM Abstract

Perfusion fraction mapping in the prostate with state-of-the-art intravoxel incoherent motion (IVIM) MRI

Accepted
Malwina Molendowska 1,2, Ivan A Rashid3, Kieran Foley4, Lars Mueller5, Lars E Olsson3,6, Patrik Brynolfsson3,6, Filip Szczepankiewicz1
1Department of Medical Radiation Physics, Lund, Sweden, Lund University, Lund, Sweden
2Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff, United Kingdom, Cardiff University, Cardiff, United Kingdom
3Department of Translational Medicine, Medical Radiation Physics, Malmö, Sweden, Lund University, Lund, Sweden
4Division of Cancer and Genetics, School of Medicine, Cardiff, United Kingdom, Cardiff University, Cardiff, United Kingdom
5Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, Leeds, United Kingdom, University of Leeds, Leeds, United Kingdom
6Department of Hematology, Oncology and Radiation Physics, Radiation Physics, Lund, Sweden, Skåne University Hospital, lund, Sweden
Presenting Author: Malwina Molendowska

Synopsis

Motivation:
Goals:
Approach:
Results:
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here. Log in if you are a member or registered attendee with access.

Full abstracts, figures, and presentations for Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition are available to registered attendees. This content becomes freely available to the public roughly two years after the meeting.

To request or purchase access, contact the ISMRM Central Office at info@ismrm.org.

Log in

References

1. Hompland T, Fjeldbo CS, Lyng H. Tumor Hypoxia as a Barrier in Cancer Therapy: Why Levels Matter. Cancers 2021, Vol 13, Page 499. 2021;13(3):499. doi:10.3390/CANCERS13030499 [doi]
2. Ahlgren A, Knutsson L, Wirestam R, et al. Quantification of microcirculatory parameters by joint analysis of flow-compensated and non-flow-compensated intravoxel incoherent motion (IVIM) data. NMR Biomed. 2016;29(5):640-649. doi:10.1002/NBM.3505 [doi]
3. Wetscherek A, Stieltjes B, Laun FB. Flow-compensated intravoxel incoherent motion diffusion imaging. Magn Reson Med. 2015;74(2):410-419. doi:10.1002/MRM.25410/ASSET/SUPINFO/MRM25410-SUP-0001-SUPPINFO01.PDF [doi]
4. Kimmlingen R. Pioneers of Connectome gradients. MAGENTOM Flash. 2017;68(2):122-136.
5. Jones DK, Alexander DC, Bowtell R, et al. Microstructural imaging of the human brain with a ‘super-scanner’: 10 key advantages of ultra-strong gradients for diffusion MRI. Neuroimage. 2018;182:8-38. doi:10.1016/J.NEUROIMAGE.2018.05.047 [doi]
6. Meyer CH, Hu BS, Nishimura DG, Macovski A. Fast Spiral Coronary Artery Imaging. Magn Reson Med. 1992;28(2). doi:10.1002/mrm.1910280204 [doi]
7. Molendowska M, Mueller L, Fasano F, Jones DK, Tax CM, Engel M. Giving the prostate the boost it needs: Spiral diffusion MRI using a high‐performance whole‐body gradient system for high b‐values at short echo times. Magnetic Resonance in Medicine. 2025 Mar; 93(3):1256-72. doi.org/10.1002/mrm.30351 [doi]
8. Wilm BJ, Nagy Z, Barmet C, et al. Diffusion MRI with concurrent magnetic field monitoring. Magn Reson Med. 2015;74(4):925-933. doi:10.1002/MRM.25827 [doi]
9. Wilm BJ, Barmet C, Gross S, et al. Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI. Magn Reson Med. 2017;77(1):83-91. doi:10.1002/mrm.26493 [doi]
10. Dietrich BE, Brunner DO, Wilm BJ, et al. A field camera for MR sequence monitoring and system analysis. Magn Reson Med. 2016;75(4):1831-1840. doi:10.1002/MRM.25770 [doi]
11. Lustig M, Kim SJ, Pauly JM. A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectories. IEEE Trans Med Imaging. 2008;27(6):866-873. doi:10.1109/TMI.2008.922699 [doi]
12. Wilm BJ, Barmet C, Pavan M, Pruessmann KP. Higher order reconstruction for MRI in the presence of spatiotemporal field perturbations. Magn Reson Med. 2011;65(6):1690-1701. doi:10.1002/mrm.22767 [doi]
13. Wilm BJ, Nagy Z, Barmet C, et al. Diffusion MRI with concurrent magnetic field monitoring. Magn Reson Med. 2015;74(4):925-933. doi:10.1002/MRM.25827 [doi]
14. Pruessmann KP, Weiger M, Börnert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med. 2001;46(4):638-651. doi.org/10.1002/mrm.1241 [doi]
15. Dietrich BE, Brunner DO, Wilm BJ, et al. A field camera for MR sequence monitoring and system analysis. Magn Reson Med. 2016;75(4):1831-1840. doi:10.1002/MRM.25770 [doi]
16. Manzano Patron JP, Moeller S, Andersson JL, Ugurbil K, Yacoub E, Sotiropoulos SN. Denoising diffusion MRI: Considerations and implications for analysis. Imaging Neuroscience. 2024 Jan 9;2:1-29. doi.org/10.1162/imag_a_00060 [doi]
17. Veraart J, Novikov DS, Christiaens D, Ades-Aron B, Sijbers J, Fieremans E. Denoising of diffusion MRI using random matrix theory. Neuroimage. 2016 Nov 15;142:394-406. doi.org/10.1016/j.neuroimage.2016.08.016 [doi]
18. Does MD, Olesen JL, Harkins KD, Serradas‐Duarte T, Gochberg DF, Jespersen SN, Shemesh N. Evaluation of principal component analysis image denoising on multi‐exponential MRI relaxometry. Magnetic resonance in medicine. 2019 Jun;81(6):3503-14. doi.org/10.1002/mrm.27658 [doi]
19. Klein S, Staring M, Murphy K, Viergever MA, Pluim JPW. Elastix: A toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 2010;29(1). doi:10.1109/TMI.2009.2035616 [doi]
20. Rashid I A, Szczepankiewicz F, Gunnlaugsson A, Olsson L E, Brynolfsson P. Effect of inaccurate b-values from imaging gradients on intravoxel incoherent motion. Magnetic Resonance in Medicine. 2025. doi.org/10.1002/mrm.30579 [doi]
21. Funck C, Laun FB, Wetscherek A. Characterization of the diffusion coefficient of blood. Magnetic resonance in medicine. 2018 May;79(5):2752-8. doi.org/10.1002/mrm.26919 [doi]
22. Petersson E, Sohlin M, Ljungberg M, Jalnefjord O. Improving accuracy and precision of intra-voxel incoherent motion parameter estimates with b-value optimization and flow compensation. Book of Abstracts ESMRMB 2024 Online 40th Annual Scientific Meeting 2–5 October 2024. Magn Reson Mater Phy 37 (Suppl 1), 1–781 (2024). doi.org/10.1007/s10334-024-01191-6 [doi]
23. Szczepankiewicz F, Sjölund J. Cross-term-compensated gradient waveform design for tensor-valued diffusion MRI. Journal of Magnetic Resonance. 2021;328:106991. doi:10.1016/J.JMR.2021.106991 [doi]

Cite this abstract