Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition
9 May 2026 – 14 May 2026 · Cape Town, South Africa
564-02-002 ISMRM Abstract

Combined-echo Helical Stack-of-Stars Imaging for Rapid Magnetic Resonance Temperature Imaging

Accepted
Michael Malmberg1, Henrik Odéen 1, Dennis Parker2
1Radiology & Imaging Sciences, University of Utah, Salt Lake City, United States of America
2University of Utah School of Medicine, Salt Lake City, United States of America
Presenting Author: Henrik Odéen

Synopsis

Motivation:
Goals:
Approach:
Results:
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here. Log in if you are a member or registered attendee with access.

Full abstracts, figures, and presentations for Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition are available to registered attendees. This content becomes freely available to the public roughly two years after the meeting.

To request or purchase access, contact the ISMRM Central Office at info@ismrm.org.

Log in

References

1. Malmberg MA, Odéen H, Kim SE, Parker DL. The effect of concomitant gradient fields on MRI with long readout radial-based trajectories. Magn Reson Med. 2025;94(3):949-964. doi:10.1002/mrm.30521 [doi]
2. Silva AC, Barbier EL, Lowe IJ, Koretsky AP. Radial Echo-Planar Imaging. J Magn Reson. 1998;135(1):242-247. doi:10.1006/jmre.1998.1547 [doi]
3. Lee GR, Griswold MA, Tkach JA. Rapid 3D radial multi-echo functional magnetic resonance imaging. NeuroImage. 2010;52(4):1428-1443. doi:10.1016/j.neuroimage.2010.05.004 [doi]
4. Wundrak S, Paul J, Ulrici J, Hell E, Rasche V. A Small Surrogate for the Golden Angle in Time-Resolved Radial MRI Based on Generalized Fibonacci Sequences. IEEE Trans Med Imaging. 2015;34(6):1262-1269. doi:10.1109/TMI.2014.2382572 [doi]
5. Farrer AI, Odéen H, de Bever J, et al. Characterization and evaluation of tissue-mimicking gelatin phantoms for use with MRgFUS. J Ther Ultrasound. 2015;3(1):9. doi:10.1186/s40349-015-0030-y [doi]
6. Thangavel K, Saritaş EÜ. Aqueous paramagnetic solutions for MRI phantoms at 3 T: A detailed study on relaxivities. Turk J Electr Eng Comput Sci. 2017;25(3):2108-2121. Accessed October 22, 2021. https://journals.tubitak.gov.tr/elektrik/abstract.htm?id=20688
7. Parker DL, Payne A, Odéen H. A k-space-based method to measure and correct for temporal B field variations in MR temperature imaging. Magn Reson Med. 2022;88(3):1098-1111. doi:10.1002/mrm.29275 [doi]
8. Pipe JG, Menon P. Sampling density compensation in MRI: Rationale and an iterative numerical solution. Magn Reson Med. 1999;41(1):179-186. doi:10.1002/(SICI)1522-2594(199901)41:1<179::AID-MRM25>3.0.CO;2-V [doi]
9. Beatty PJ, Nishimura DG, Pauly JM. Rapid gridding reconstruction with a minimal oversampling ratio. IEEE Trans Med Imaging. 2005;24(6):799-808. doi:10.1109/TMI.2005.848376 [doi]
10. Dale B, Wendt M, Duerk JL. A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories. IEEE Trans Med Imaging. 2001;20(3):207-217. doi:10.1109/42.918471 [doi]
11. Jackson JI, Meyer CH, Nishimura DG, Macovski A. Selection of a convolution function for Fourier inversion using gridding (computerised tomography application). IEEE Trans Med Imaging. 1991;10(3):473-478. doi:10.1109/42.97598 [doi]
12. Song HK, Dougherty L. k-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI. Magn Reson Med. 2000;44(6):825-832. doi:10.1002/1522-2594(200012)44:6<825::AID-MRM2>3.0.CO;2-D [doi]
13. Winkelmann S, Schaeffter T, Koehler T, Eggers H, Doessel O. An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI. IEEE Trans Med Imaging. 2007;26(1):68-76. doi:10.1109/TMI.2006.885337 [doi]
14. Rieke V, Pauly KB. MR Thermometry. J Magn Reson Imaging JMRI. 2008;27(2):376-390. doi:10.1002/jmri.21265 [doi]
15. Adams-Tew SI, Johnson S, Odéen H, Parker DL, Payne A. Validation of a drift-corrected 3D MR temperature imaging sequence for breast MR-guided focused ultrasound treatments. Magn Reson Imaging. 2023;96:126-134. doi:10.1016/j.mri.2022.12.006 [doi]

Cite this abstract