Distortion-free, submillimeter-isotropic-resolution diffusion MRI with gSlider BUDA-EPI and multi-coil dynamic B0shimming

Accepted
Congyu Liao 1, Berkin Bilgic1, Qiyuan Tian1, Jason Stockmann1, Qiuyun Fan1, Siddharth Srinivasan Iyer1,2, Fuyixue Wang1,3, Chanon Ngamsombat1,4, Xiaozhi Cao1, Mary Kate Manhard1, Susie Huang1, Lawrence L Wald1, Kawin Setsompop1
1Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, United States of America
2Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, United States of America
3Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, United States of America
4Department of Radiology, Faculty of Medicine, Siriraj Hospital, Bangkok, Thailand
Presenting Author: Congyu Liao
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here.

This content is freely available and no longer restricted to registered attendees. Log in or create a free account to view it.

Log in

References

1. Leuze CWU, Anwander A, Bazin PL, et al. Layer-specific intracortical connectivity revealed with diffusion MRI. Cereb. Cortex 2014;24:328–339.
2. McNab JA, Polimeni JR, Wang R, et al. Surface-based analysis of diffusion orientation for identifying architectonic domains in the in vivo human cortex. Neuroimage 2013;69:87–100.
3. Setsompop K, Fan Q, Stockmann J, et al. High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS). Magn. Reson. Med. 2018;79:141–151.
4. Liao C, Stockmann J, Tian Q, et al. High‐fidelity, high‐isotropic‐resolution diffusion imaging through gSlider acquisition with and T 1 corrections and integrated ΔB0/Rx shim array. Magn. Reson. Med. 2019;83:56–67.
5. Stockmann JP, Witzel T, Keil B, et al. A 32-channel combined RF and B0shim array for 3T brain imaging. Magn. Reson. Med. 2016;75:441–451.
6. Jenkinson M, Beckmann CF, Behrens TEJ, Woolrich MW, Smith SM. Fsl. Neuroimage 2012;62:782–790.
7. Zahneisen B, Aksoy M, Maclaren J, Wuerslin C, Bammer R. Extended hybrid-space SENSE for EPI: Off-resonance and eddy current corrected joint interleaved blip-up/down reconstruction. Neuroimage 2017;153:97–108.
8. Setsompop K, Gagoski BA, Polimeni JR, Witzel T, Wedeen VJ, Wald LL. Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magn. Reson. Med. 2012;67:1210–1224.
9. Fischl B. FreeSurfer. Neuroimage 2012;62:774–781.
10. Greve DN, Fischl B. Accurate and robust brain image alignment using boundary-based registration. Neuroimage 2009;48:63–72.
11. Jeurissen B, Tournier J-D, Dhollander T, Connelly A, Sijbers J. Multi-tissue constrained spherical deconvolution for improved analysis of multi-shell diffusion MRI data. Neuroimage 2014;103:411–426.

Cite this abstract