Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition
9 May 2026 – 14 May 2026
· Cape Town, South Africa
604-01-004
ISMRM Abstract
7T spinal cord fMRI using slice-wise frequency and xyz-gradient B0 shimming
Primary:
Physics & Engineering - High-Field MRI
Secondary:
Physics & Engineering - Shims
604-01-004 · Advanced MRI Techniques for Spinal Cord Structure, Function, and Physiology
· Thursday, 14 May, 8:30 AM–10:20 AM · Ballroom East
Keywords:ArtifactsSpinal Cord7TB0 shimmingFmri
Accepted
Alexandre D'Astous 1,2, Caroline Landelle3, Arnaud Bréhéret1, Antoine Guénette1, Julien Doyon3, Eva Alonso Ortiz1,2, Julien Cohen-Adad1,2,4,5
1Polytechnique Montréal, Montréal, Canada
2CHU Sainte-Justine Research Center, Montréal, Canada, Canada
3Department of Neurology and Neurosurgery, Montreal Neurological Institute, McGill University, Montreal, Canada
4Mila - Quebec AI Institute, Montreal, Canada
5Functional Neuroimaging Unit, Montreal, Canada
Presenting Author: Alexandre D'Astous
Synopsis
Motivation:
Goals:
Approach:
Results:
Full abstract & presentation
The full text, figures, and any recorded presentation for this abstract are not shown here. Log in if you are a member or registered attendee with access.
Full abstracts, figures, and presentations for Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition are available to registered attendees. This content becomes freely available to the public roughly two years after the meeting.
To request or purchase access, contact the ISMRM Central Office at info@ismrm.org.
1. Landelle C, Lungu O, Vahdat S, Kavounoudias A, Marchand-Pauvert V, De Leener B, et al. Investigating the human spinal sensorimotor pathways through functional magnetic resonance imaging. Neuroimage. 2021 Dec 15;245(118684):118684. Available from: http://dx.doi.org/10.1016/j.neuroimage.2021.118684 [doi]
2. Blamire AM, Rothman DL, Nixon T. Dynamic shim updating: a new approach towards optimized whole brain shimming. Magn Reson Med. 1996 Jul;36(1):159–65. Available from: http://dx.doi.org/10.1002/mrm.1910360125 [doi]
3. de Graaf RA, Brown PB, McIntyre S, Rothman DL, Nixon TW. Dynamic shim updating (DSU) for multislice signal acquisition. Magn Reson Med. 2003 Mar;49(3):409–16. Available from: http://dx.doi.org/10.1002/mrm.10404 [doi]
4. Morrell G, Spielman D. Dynamic shimming for multi-slice magnetic resonance imaging. Magn Reson Med. 1997 Sep;38(3):477–83. Available from: http://dx.doi.org/10.1002/mrm.1910380316 [doi]
5. Sengupta S, Welch EB, Zhao Y, Foxall D, Starewicz P, Anderson AW, et al. Dynamic B0 shimming at 7 T. Magn Reson Imaging. 2011 May;29(4):483–96. Available from: https://doi.org/10.1016/j.mri.2011.01.002 [doi]
6. Koch KM, McIntyre S, Nixon TW, Rothman DL, de Graaf RA. Dynamic shim updating on the human brain. Vol. 180, Journal of Magnetic Resonance. 2006. p. 286–96. Available from: http://dx.doi.org/10.1016/j.jmr.2006.03.007 [doi]
7. Kaptan M, Vannesjo SJ, Mildner T, Horn U, Hartley-Davies R, Oliva V, et al. Automated slice-specific z-shimming for functional magnetic resonance imaging of the human spinal cord. Hum Brain Mapp. 2022 Aug 8; Available from: http://dx.doi.org/10.1002/hbm.26018 [doi]
8. Alonso-Ortiz E, Papp D, D’Astous A, Cohen-Adad J. Dynamic shimming in the cervical spinal cord for multi-echo gradient-echo imaging at 3 T. Neuroimage Rep. 2023 Mar;3(1):100150. Available from: https://doi.org/10.1016/j.ynirp.2022.100150 [doi]
9. Vannesjo J, Shi Y, Tracey I, Miller KL, Clare S. Slice-wise first-order shimming of the human spinal cord at 7T. In: Proc Intl Soc Mag Reson Med. FMRIB centre, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom; 2017.
10. Horn U, Vannesjo SJ, Gross-Weege N, Trampel R, Revina Y, Kaptan M, et al. Ultra-high-field fMRI reveals layer-specific responses in the human spinal cord. bioRxiv. 2025. Available from: https://doi.org/10.1101/2025.07.17.665316 [doi]
11. De Leener B, Lévy S, Dupont SM, Fonov VS, Stikov N, Louis Collins D, et al. SCT: Spinal Cord Toolbox, an open-source software for processing spinal cord MRI data. Neuroimage. 2017 Jan 15;145(Pt A):24–43. Available from: http://dx.doi.org/10.1016/j.neuroimage.2016.10.009 [doi]
12. D’Astous A, Cereza G, Papp D, Gilbert KM, Stockmann JP, Alonso-Ortiz E, et al. Shimming toolbox: An open-source software toolbox for B0 and B1 shimming in MRI. Magn Reson Med [Internet]. 2023 Apr;89(4):1401–17. Available from: https://doi.org/10.1002/mrm.29528 [doi]
13. Breheret A, D’Astous A, Ma Y, Stockmann JP, Cohen-Adad J. Impact of through-slice gradient optimization for dynamic slice-wise shimming in the cervico-thoracic spinal cord. Magn Reson Med. 2025 Sep;94(3):1090–102. Available from: http://dx.doi.org/10.1002/mrm.30543 [doi]
14. Bédard S, Valošek J, Oliva V, Weber KA Ii, Cohen-Adad J. Rootlets-based registration to the PAM50 spinal cord template. Imaging Neurosci (Camb). 2025 Aug 26;3(IMAG.a.123). Available from: http://dx.doi.org/10.1162/IMAG.a.123 [doi]