2025 ISMRM and ISMRT Annual Meeting and Exhibition
10 May 2025 – 15 May 2025 · Honolulu, HI, United States of America
1365 ISMRM Abstract

Robust Nyquist ghost correction for high-resolution EPI using multishot dual-polarity GRAPPA reconstruction

Accepted
Yuancheng Jiang 1, Yohan Jun2,3, Qiang Liu4, Wen Zhong1, Yogesh Rathi3,4, Hua Guo1, Berkin Bilgic2,3
1Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China
2Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, United States of America
3Harvard Medical School, Boston, United States of America
4Department of Psychiatry and Radiology, Brigham and Women's Hospital, Boston, United States of America
Presenting Author: Yuancheng Jiang
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here. Log in if you are a member or registered attendee with access.

Full abstracts, figures, and presentations for 2025 ISMRM and ISMRT Annual Meeting and Exhibition are available to registered attendees. This content becomes freely available to the public on 15 May 2027.

To request or purchase access, contact the ISMRM Central Office at support@ismrm.org.

Log in

References

1. Bammer R, Stollberger R, Augustin M, Simbrunner J, Offenbacher H, Kooijman H, Ropele S, Kapeller P, Wach P, Ebner F, Fazekas F. Diffusion-weighted Imaging with Navigated Interleaved Echo-planar Imaging and a Conventional Gradient System. Radiology 1999;211(3):799-806.
2. Butts K, Riederer SJ, Ehman RL, Thompson RM, Jack CR. Interleaved echo planar imaging on a standard MRI system. Magn Reson Med 1994;31(1):67-72.
3. Pan Z, Ma X, Dai E, Auerbach EJ, Guo H, Uğurbil K, Wu X. Reconstruction for 7T high - resolution whole - brain diffusion MRI using two - stage N/2 ghost correction and L1 - SPIRiT without single - band reference. Magn Reson Med 2023;89(5):1915-1930.
4. Ma R, Akcakaya M, Moeller S, Auerbach E, Ugurbil K, Van de Moortele PF. A field-monitoring-based approach for correcting eddy-current-induced artifacts of up to the 2(nd) spatial order in human-connectome-project-style multiband diffusion MRI experiment at 7T: A pilot study. Neuroimage 2020;216:116861.
5. Ramos - Llordén G, Lobos RA, Kim TH, Tian Q, Witzel T, Lee HH, Scholz A, Keil B, Yendiki A, Bilgiç B, Haldar JP, Huang SY. High - fidelity, high - spatial - resolution diffusion magnetic resonance imaging of ex vivo whole human brain at ultra ‐ high gradient strength with structured low ‐ rank echo ‐ planar imaging ghost correction. NMR Biomed 2023;36(2):e4831.
6. Hoge WS, Polimeni JR. Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data. Magn Reson Med 2016;76(1):32-44.
7. Haldar JP. Low-Rank Modeling of Local k-Space Neighborhoods (LORAKS) for Constrained MRI. IEEE Trans Med Imaging 2014;33(3):668-681.
8. Mani M, Jacob M, Kelley D, Magnotta V. Multi-shot sensitivity-encoded diffusion data recovery using structured low-rank matrix completion (MUSSELS). Magn Reson Med 2017;78(2):494-507.
9. Hoge WS, Tan H, Kraft RA. Robust EPI Nyquist ghost elimination via spatial and temporal encoding. Magn Reson Med 2010;64(6):1781-1791.
10. Layton KJ, Kroboth S, Jia F, Littin S, Yu H, Leupold J, Nielsen J-F, Stöcker T, Zaitsev M. Pulseq: A rapid and hardware-independent pulse sequence prototyping framework. Magn Reson Med 2017;77(4):1544-1552.

Cite this abstract