References
1. Marshall, H., Stewart, N. J., Chan, H. F., Rao, M., Norquay, G., & Wild, J. M. (2021). In vivo methods and applications of xenon-129 magnetic resonance. Progress in nuclear magnetic resonance spectroscopy, 122, 42–62. https://doi.org/10.1016/j.pnmrs.2020.11.002
[doi]
2. Stewart, N. J., Smith, L. J., Chan, H. F., Eaden, J. A., Rajaram, S., Swift, A. J., Weatherley, N. D., Biancardi, A., Collier, G. J., Hughes, D., Klafkowski, G., Johns, C. S., West, N., Ugonna, K., Bianchi, S. M., Lawson, R., Sabroe, I., Marshall, H., & Wild, J. M. (2022). Lung MRI with hyperpolarised gases: current & future clinical perspectives. The British journal of radiology, 95(1132), 20210207. https://doi.org/10.1259/bjr.20210207
[doi]
3. Stewart, N. J., Norquay, G., Griffiths, P. D., & Wild, J. M. (2015). Feasibility of human lung ventilation imaging using highly polarized naturally abundant xenon and optimized three-dimensional steady-state free precession. Magnetic resonance in medicine, 74(2), 346–352. https://doi.org/10.1002/mrm.25732
[doi]
4. He, M., Zha, W., Tan, F., Rankine, L., Fain, S., & Driehuys, B. (2019). A Comparison of Two Hyperpolarized 129Xe MRI Ventilation Quantification Pipelines: The Effect of Signal to Noise Ratio. Academic radiology, 26(7), 949–959. https://doi.org/10.1016/j.acra.2018.08.015
[doi]
5. Stewart, N. J., de Arcos, J., Biancardi, A. M., Collier, G. J., Smith, L. J., Norquay, G., Marshall, H., Brau, A. C. S., Lebel, R. M., & Wild, J. M. (2024). Improving Xenon-129 lung ventilation image SNR with deep-learning based image reconstruction. Magnetic resonance in medicine, 92(6), 2546–2559. https://doi.org/10.1002/mrm.30250
[doi]
6. Bdaiwi AS, Willmering MM, Plummer JW, et al. 129Xe Image Processing Pipeline: An open-source, graphical user interface application for the analysis of hyperpolarized 129Xe MRI. Magn Reson Med. 2025; 93(3): 1220-1237. doi: 10.1002/mrm.30347
[doi]
7. Bdaiwi, A. S., Willmering, M. M., Hussain, R., Hysinger, E., Woods, J. C., Walkup, L. L., & Cleveland, Z. I. (2025). Comparative evaluation of supervised and unsupervised deep learning strategies for denoising hyperpolarized 129Xe lung MRI. Magnetic resonance in medicine, 10.1002/mrm.70033. Advance online publication. https://doi.org/10.1002/mrm.70033
[doi]
8. Muckley, M. J., Ades-Aron, B., Papaioannou, A., Lemberskiy, G., Solomon, E., Lui, Y. W., Sodickson, D. K., Fieremans, E., Novikov, D. S., & Knoll, F. (2021). Training a neural network for Gibbs and noise removal in diffusion MRI. Magnetic resonance in medicine, 85(1), 413–428. https://doi.org/10.1002/mrm.28395
[doi]
9. Niedbalski, P. J., Hall, C. S., Castro, M., Eddy, R. L., Rayment, J. H., Svenningsen, S., Parraga, G., Zanette, B., Santyr, G. E., Thomen, R. P., Stewart, N. J., Collier, G. J., Chan, H. F., Wild, J. M., Fain, S. B., Miller, G. W., Mata, J. F., Mugler, J. P., 3rd, Driehuys, B., Willmering, M. M., … Woods, J. C. (2021). Protocols for multi-site trials using hyperpolarized 129 Xe MRI for imaging of ventilation, alveolar-airspace size, and gas exchange: A position paper from the 129 Xe MRI clinical trials consortium. Magnetic resonance in medicine, 86(6), 2966–2986. https://doi.org/10.1002/mrm.28985
[doi]
10. "Picture Thresholding Using an Iterative Selection Method," in IEEE Transactions on Systems, Man, and Cybernetics, vol. 8, no. 8, pp. 630-632, Aug. 1978, doi: 10.1109/TSMC.1978.4310039.
[doi]
11. Eddy, R. L., Svenningsen, S., McCormack, D. G., & Parraga, G. (2018). What is the minimal clinically important difference for helium-3 magnetic resonance imaging ventilation defects?. The European respiratory journal, 51(6), 1800324. https://doi.org/10.1183/13993003.00324-2018
[doi]
12. Smith, L. J., Collier, G. J., Marshall, H., Hughes, P. J. C., Biancardi, A. M., Wildman, M., Aldag, I., West, N., Horsley, A., & Wild, J. M. (2018). Patterns of regional lung physiology in cystic fibrosis using ventilation magnetic resonance imaging and multiple-breath washout. The European respiratory journal, 52(5), 1800821. https://doi.org/10.1183/13993003.00821-2018
[doi]
13. Tzeng, Y. S., Lutchen, K., & Albert, M. (2009). The difference in ventilation heterogeneity between asthmatic and healthy subjects quantified using hyperpolarized 3He MRI. Journal of applied physiology (Bethesda, Md. : 1985), 106(3), 813–822. https://doi.org/10.1152/japplphysiol.01133.2007
[doi]
14. Bdaiwi, A. S., Willmering, M. M., Wang, H., & Cleveland, Z. I. (2023). Diffusion weighted hyperpolarized 129 Xe MRI of the lung with 2D and 3D (FLORET) spiral. Magnetic resonance in medicine, 89(4), 1342–1356. https://doi.org/10.1002/mrm.29518
[doi]
15. Chan, H. F., Stewart, N. J., Norquay, G., Collier, G. J., & Wild, J. M. (2018). 3D diffusion-weighted 129 Xe MRI for whole lung morphometry. Magnetic resonance in medicine, 79(6), 2986–2995. https://doi.org/10.1002/mrm.26960
[doi]
16. Collier, G. J., Eaden, J. A., Hughes, P. J. C., Bianchi, S. M., Stewart, N. J., Weatherley, N. D., Norquay, G., Schulte, R. F., & Wild, J. M. (2021). Dissolved 129 Xe lung MRI with four-echo 3D radial spectroscopic imaging: Quantification of regional gas transfer in idiopathic pulmonary fibrosis. Magnetic resonance in medicine, 85(5), 2622–2633. https://doi.org/10.1002/mrm.28609
[doi]