Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition
9 May 2026 – 14 May 2026
· Cape Town, South Africa
563-06-001
ISMRM Abstract
Improved glioma grading and IDH mutation status prediction with QUASS-based AREX analysis using CEST MRI
Primary:
Contrast Mechanisms - CEST / APT / NOE
Secondary:
Neuro - Tumors
563-06-001 · From Molecular Signatures to Surgical Guidance: Cutting-Edge MRI in Brain Tumor Care
· Wednesday, 13 May, 4:55 PM–5:50 PM · Digital Posters Row D
Keywords:IDH mutationGlioma GradingChemical exchange saturation transferAmide proton transfer
1Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
2Huashan Hospital, Fudan University, China
3Shanghai United Imaging Healthcare Co., Ltd, Shanghai, China
4Research Center for Medical AI, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
Presenting Author: Yin Wu
Synopsis
Motivation:
Goals:
Approach:
Results:
Full abstract & presentation
The full text, figures, and any recorded presentation for this abstract are not shown here. Log in if you are a member or registered attendee with access.
Full abstracts, figures, and presentations for Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition are available to registered attendees. This content becomes freely available to the public roughly two years after the meeting.
To request or purchase access, contact the ISMRM Central Office at info@ismrm.org.
1. Zhou J, Tryggestad E, Wen Z, et al. Differentiation between glioma and radiation necrosis using molecular magnetic resonance imaging of endogenous proteins and peptides. Nat Med 2011;17(1):130-134. doi: 10.1038/nm.2268. [doi]
2. Zhou J, Heo HY, Knutsson L, et al. APT-weighted MRI: Techniques, current neuro applications, and challenging issues. J Magn Reson Imaging. 2019;50(2):347-64. doi: 10.1002/jmri.26645. [doi]
3. Zu Z. Towards the complex dependence of MTRasym on T1w in amide proton transfer (APT) imaging. NMR Biomed 2018;31(7):e3934. doi: 10.1002/nbm.3934. [doi]
4. Zhou J, Zaiss M, Knutsson L, et al. Review and consensus recommendations on clinical APT-weighted imaging approaches at 3T: Application to brain tumors. Magn Reson Med. 2022;88(2):546-74. doi: 10.1002/mrm.29241. [doi]
5. Zaiss M, Schmitt B, Bachert P. Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra. J Magn Reson. 2011;211(2):149-55. doi: 10.1016/j.jmr.2011.05.001. [doi]
6. Zaiss M, Bachert P. Chemical exchange saturation transfer (CEST) and MR Z-spectroscopy in vivo: a review of theoretical approaches and methods. Phys Med Biol. 2013;58(22):221-69. doi: 10.1088/0031-9155/58/22/R221. [doi]
7. Zaiss M, Xu J, Goerke S, et al. Inverse Z-spectrum analysis for spillover-, MT-, and T1-corrected steady-state pulsed CEST-MRI – application to pH-weighted MRI of acute stroke. NMR Biomed 2014;27(3):240-252. doi: 10.1002/nbm.3054. [doi]
8. Xu J, Zaiss M, Zu Z, et al. On the origins of chemical exchange saturation transfer (CEST) contrast in tumors at 9.4 T. NMR Biomed. 2014;27(4):406-16. doi: 10.1002/nbm.3075. [doi]
9. Sun PZ. Quasi-steady state chemical exchange saturation transfer (QUASS CEST) analysis-correction of the finite relaxation delay and saturation time for robust CEST measurement. Magn Reson Med 2021;85(6):3281-3289. doi: 10.1002/mrm.28653. [doi]
10. Sun PZ. Quasi-steady-state (QUASS) reconstruction enhances T(1) normalization in apparent exchange-dependent relaxation (AREX) analysis: A reevaluation of T(1) correction in quantitative CEST MRI of rodent brain tumor models. Magn Reson Med. 2024;92(1):236-45. doi: 10.1002/mrm.30056. [doi]
11. Liu Z, Qian Y, Liu H, et al. Mitigation of T1 impact for unbiased tumor magnetic resonance amide proton transfer imaging at 3T. Radiology Advances. 2025;2(2):umaf011. doi: 10.1093/radadv/umaf011. [doi]
12. Kim M, Gillen J, Landman BA, Zhou J, van Zijl PCM. Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments. Magn Reson Med 2009;61(6):1441-1450. doi: 10.1002/mrm.21873. [doi]
13. Zhang XY, Zhai Y, Jin Z, Li C, Sun PZ, Wu Y. Preliminary demonstration of in vivo quasi-steady-state CEST postprocessing-Correction of saturation time and relaxation delay for robust quantification of tumor MT and APT effects. Magn Reson Med 2021;86(2):943-953. doi: 10.1002/mrm.28764. [doi]
14. Xu Z, Ke C, Liu J, et al. Diagnostic performance between MR amide proton transfer (APT) and diffusion kurtosis imaging (DKI) in glioma grading and IDH mutation status prediction at 3T. Eur J Radiol. 2021;134:109466. doi: 10.1016/j.ejrad.2020.109466. [doi]