Dual-polarity SENSE with calibration refinement enables robust Nyquist ghost correction on a high-performance gradient system

Accepted
Yuancheng Jiang 1, Gabriel Ramos Llorden2,3, Shohei Fujita2,3, Jaejin Cho2,3, Xingwang Yong2,3, Hua Guo1, Berkin Bilgic2,3
1Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
2Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, United States of America
3Department of Radiology, Harvard Medical School, Boston, United States of America
Presenting Author: Yuancheng Jiang
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here.

This content is freely available and no longer restricted to registered attendees. Log in or create a free account to view it.

Log in

References

1. Hoge WS, Polimeni JR. Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data. Magnetic Resonance in Medicine 2016;76(1):32-44.
2. Lobos RA, Hoge WS, Javed A, et al. Robust autocalibrated structured low‐rank EPI ghost correction. Magnetic Resonance in Medicine 2021;85(6):3403-3419.
3. Liao C, Bilgic B, Tian Q, et al. Distortion-free, high-isotropic-resolution diffusion MRI with gSlider BUDA-EPI and multicoil dynamic B0 shimming. Magnetic Resonance in Medicine 2021;86(2):791-803.
4. Dong Z, Wang F, Reese TG, Bilgic B, Setsompop K. Echo planar time‐resolved imaging with subspace reconstruction and optimized spatiotemporal encoding. Magnetic Resonance in Medicine 2020;84(5):2442-2455.
5. Uecker M, Lai P, Murphy MJ, et al. ESPIRiT-an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA. Magnetic Resonance in Medicine 2014;71(3):990-1001.
6. Hoge WS, Tan H, Kraft RA. Robust EPI Nyquist ghost elimination via spatial and temporal encoding. Magnetic Resonance in Medicine 2010;64(6):1781-1791.
7. Chang YV, Zhou K, Hoge WS, et al. Inter-frame phase alignment for Echo Planar Imaging calibration data acquired with opposite read-out polarities. Proc ISMRM. 2019, 27: 928.
8. Huang SY, Witzel T, Keil B, et al. Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome. NeuroImage 2021;243:118530.

Cite this abstract