Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition
9 May 2026 – 14 May 2026
· Cape Town, South Africa
503-02-005
ISMRM Abstract
Eddy Current Compensated Diffusion-Encoded Preparation Module for Cardiac Diffusion Tensor Imaging
Primary:
Diffusion - DWI/DTI/DKI
Secondary:
Cardiovascular - Myocardium
503-02-005 · Body Diffusion MRI
· Wednesday, 13 May, 1:40 PM–3:30 PM · Auditorium 1
Keywords:Diffusion Tensor ImagingMotion-Compensated GradientsEddy Current CompensationPreparation Module
Accepted
Sandra Haltmeier 1, Maximilian Fuetterer1, Limin Zhou2, Christian T Stoeck1,3, Kevin Moulin4, Sebastian Kozerke1
1Institute for Biomedical Engineering, University Zurich and ETH Zurich, Zurich, Switzerland
2Philips North America Clinical Science, Rochester, United States of America
3Center for Preclinical Development University of Zurich and University Hospital Zurich, Zurich, Switzerland
4Department of Cardiology, Boston Children's Hospital, Boston, United States of America
Presenting Author: Sandra Haltmeier
Synopsis
Motivation:
Goals:
Approach:
Results:
Full abstract & presentation
The full text, figures, and any recorded presentation for this abstract are not shown here. Log in if you are a member or registered attendee with access.
Full abstracts, figures, and presentations for Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition are available to registered attendees. This content becomes freely available to the public roughly two years after the meeting.
To request or purchase access, contact the ISMRM Central Office at info@ismrm.org.
1. Stoeck, C. T., von Deuster, C., Genet, M., Atkinson, D., & Kozerke, S. (2016). Second‐order motion‐compensated spin echo diffusion tensor imaging of the human heart. Magnetic resonance in medicine, 75(4), 1669-1676. https://doi.org/10.1002/mrm.25784 [doi]
2. van Gorkum, R. J., Guenthner, C., Koethe, A., Stoeck, C. T., & Kozerke, S. (2022). Characterization and correction of diffusion gradient‐induced eddy currents in second‐order motion‐compensated echo‐planar and spiral cardiac DTI. Magnetic Resonance in Medicine, 88(6), 2378-2394. https://doi.org/10.1002/mrm.29378 [doi]
3. Nguyen, C., Fan, Z., Sharif, B., He, Y., Dharmakumar, R., Berman, D. S., & Li, D. (2014). In vivo three‐dimensional high resolution cardiac diffusion‐weighted MRI: a motion compensated diffusion‐prepared balanced steady‐state free precession approach. Magnetic resonance in medicine, 72(5), 1257-1267. https://doi.org/10.1002/mrm.25038 [doi]
4. Nguyen, C., Fan, Z., Xie, Y., Pang, J., Speier, P., Bi, X., ... & Li, D. (2016). In vivo diffusion‐tensor MRI of the human heart on a 3 tesla clinical scanner: An optimized second order (M2) motion compensated diffusion‐preparation approach. Magnetic resonance in medicine, 76(5), 1354-1363. https://doi.org/10.1002/mrm.26380 [doi]
5. Stoeck, C. T., von Deuster, C., van Gorkum, R. J., & Kozerke, S. (2020). Motion and eddy current–induced signal dephasing in in vivo cardiac DTI. Magnetic resonance in medicine, 84(1), 277-288. https://doi.org/10.1002/mrm.28132 [doi]
6. Finsterbusch, J. (2009). Eddy‐current compensated diffusion weighting with a single refocusing RF pulse. Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine, 61(3), 748-754. https://doi.org/10.1002/mrm.21899 [doi]
7. Aliotta, E., Moulin, K., & Ennis, D. B. (2018). Eddy current–nulled convex optimized diffusion encoding (EN‐CODE) for distortion‐free diffusion tensor imaging with short echo times. Magnetic resonance in medicine, 79(2), 663-672. https://doi.org/10.1002/mrm.26709 [doi]
8. Middione, M. J., Loecher, M., Cao, X., Setsompop, K., & Ennis, D. B. (2024). Pre‐excitation gradients for eddy current nulled convex optimized diffusion encoding (Pre‐ENCODE). Magnetic Resonance in Medicine, 92(2), 573-585. https://doi.org/10.1002/mrm.30068 [doi]
9. Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003). Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo. Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine, 49(1), 177-182. https://doi.org/10.1002/mrm.10308 [doi]
10. Meakin, J. A., & Jezzard, P. (2013). An optimized velocity selective arterial spin labeling module with reduced eddy current sensitivity for improved perfusion quantification. Magnetic Resonance in Medicine, 69(3), 832-838. https://doi.org/10.1002/mrm.24302 [doi]
11. Guo, J., Meakin, J. A., Jezzard, P., & Wong, E. C. (2015). An optimized design to reduce eddy current sensitivity in velocity‐selective arterial spin labeling using symmetric BIR‐8 pulses. Magnetic resonance in medicine, 73(3), 1085-1094. https://doi.org/10.1002/mrm.25227 [doi]
12. Zhang, Q., Coolen, B. F., Versluis, M. J., Strijkers, G. J., & Nederveen, A. J. (2017). Diffusion‐prepared stimulated‐echo turbo spin echo (DPsti‐TSE): an eddy current‐insensitive sequence for three‐dimensional high‐resolution and undistorted diffusion‐weighted imaging. NMR in Biomedicine, 30(7), e3719. https://doi.org/10.1002/nbm.3719 [doi]