2020 ISMRM and SMRT Virtual Conference and Exhibition
8 August 2020 – 14 August 2020 · Online, Virtual
0890 ISMRM Abstract

T2-BUDA-gSlider: fast T2mapping with blip-up/down acquisition, generalized SLIce Dithered Enhanced Resolution and subspace reconstruction

Accepted
Xiaozhi Cao 1,2,3, Congyu Liao2,3, Zijing Zhang2,4, Siddharth Srinivasan Iyer2,5, Hongjian HE1, Kawin Setsompop2,3,6, J Zhong1, Berkin Bilgic2,3,6
1Center for Brain Imaging Science and Technology, Department of Biomedical Engineering, Zhejiang University, Hangzhou, China
2Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, United States of America
3Department of Radiology, Harvard Medical School, Boston, United States of America
4State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
5Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, United States of America
6Harvard-MIT Division of Health Sciences and Technology, Cambridge, United States of America
Presenting Author: Xiaozhi Cao
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here.

This content is freely available and no longer restricted to registered attendees. Log in or create a free account to view it.

Log in

References

1. Singh P, Kaur R, Saggar K, Singh G, Kaur A. Qualitative and quantitative hippocampal MRI assessments in intractable epilepsy. Biomed Res Int. 2013;2013:480524.
2. Deoni SCL. Magnetic Resonance Relaxation and Quantitative Measurement in the Brain. In: Modo M, Bulte JWM, editors. Magnetic Resonance Neuroimaging: Methods and Protocols. Totowa, NJ: Humana Press; 2011. p 65-108.
3. Setsompop K, Fan Q, Stockmann J, Bilgic B, Huang S, Cauley SF, et al. High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS). Magn Reson Med. 2018;79(1):141-51.
4. Andersson JL, Skare S, Ashburner J. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. NeuroImage, 20(2), 870-888.
5. Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magnetic Resonance in Medicine, 1999; 42(5), 952-962.
6. Low-Rank Modeling of Local k-Space Neighborhoods (LORAKS) for Constrained MRI. IEEE Transactions on Medical Imaging, 2014; 33(3): 668-681.
7. Mani M, Jacob M, Kelley D, Magnotta V. Multi-shot sensitivity-encoded diffusion data recovery using structured low-rank matrix completion (MUSSELS). Magn Reson Med. 2017;78(2):494-507.
8. Shin PJ, Larson PE, Ohliger MA, Elad M, Pauly JM, Vigneron DB, et al. Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion. Magn Reson Med. 2014;72(4):959-70.
9. Uecker M, Lai P, Murphy MJ, Virtue P, Elad M, Pauly JM, et al. ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA. Magn Reson Med. 2014;71(3):990-1001.
10. Weigel M. Extended phase graphs: dephasing, RF pulses, and echoes - pure and simple. J Magn Reson Imaging 2015;41(2):266-295.
11. Tamir JI, Uecker M, Chen W, Lai P, Alley MT, Vasanawala SS, et al. T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med. 2017;77(1):180-95.
12. Zahneisen B, Aksoy M, Maclaren J, Wuerslin C, Bammer R. Extended hybrid-space SENSE for EPI: Off-resonance and eddy current corrected joint interleaved blip-up/down reconstruction. Neuroimage. 2017;153:97-108.

Cite this abstract