Eddy-Current-Resilient B₀ Mapping Using Spatiotemporal Encoding

Accepted
Angela Teeple 1, Ryan Smith2, Lance DelaBarre1, Ben Parkinson3, PARKER J JENKINS1, Daniel C Pizetta4, Julia Marcolan5, Edson Vidoto5, Mateus J Martins5, Brooklynn Dobson1, Alberto Tannus5, MICHAEL GARWOOD1
1Center for Magnetic Resonance Research, Dept. of Radiology, University of Minnesota, Minneapolis, United States of America
2Radiation Oncology, University of Minnesota, Minneapolis, United States of America
3Robinson Research Institute, Victoria University, Wellington, New Zealand
4Sao Carlos Institute of Physics, University of Sao Paulo, IFSC – USP, Sao Carlos, Brazil
5Centro de Imagens e Espectroscopia por Ressonância Magnética, University of Sao Paulo, Ribeirao Preto, Brazil
Presenting Author: Angela Teeple

Synopsis

Motivation:
Goals:
Approach:
Results:
Full abstract & presentation

The full text, figures, and any recorded presentation for this abstract are not shown here. Log in if you are a member or registered attendee with access.

Full abstracts, figures, and presentations for Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition are available to registered attendees. This content becomes freely available to the public roughly two years after the meeting.

To request or purchase access, contact the ISMRM Central Office at info@ismrm.org.

Log in

References

1. Jezzard P, Balaban RS. Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med. 1995;34(1):65–73. doi:10.1002/mrm.1910340111 [doi]
2. Kim YS, Cho ZH. Eddy-current-compensated field-inhomogeneity mapping in NMR imaging. Journal of Magnetic Resonance (1969). 2004 Jul 12;78(3):459–71. doi:10.1016/0022-2364(88)90132-1 [doi]
3. Theilmann RJ, et al. Integrated RF and gradient coils for portable MRI. Magn Reson Med. 2023;89(3):1112–1125. doi:10.1002/mrm.29612 [doi]
4. Silver MS, Joseph RI, Hoult DI. Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch–Riccati equation. Phys Rev A. 1985;31(4):2753–2755. doi:10.1103/PhysRevA.31.2753 [doi]
5. Tannús A, Garwood M. Improved performance of frequency-swept pulses using offset-independent adiabaticity. J Magn Reson A. 1996;120(1):133–137. doi:10.1006/jmra.1996.0110 [doi]
6. Smith RHB, Garwood D, Garwood M. Exact analytical solutions of the Bloch equation for the hyperbolic-secant and chirp pulses. Magn Reson Med. 2025; doi:10.1002/mrm.30603. [doi]
7. Lee Y, Han Y, Park HW, Watanabe H, Garwood M, Park J-Y. New phase-based B₁ mapping method using two-dimensional spin-echo imaging with hyperbolic secant pulses. Magn Reson Med. 2015;73(4):1533–1542. doi:[10.1002/mrm.25110](https://doi.org/10.1002/mrm.25110) [doi]
8. Garwood M, DelaBarre L. The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. J Magn Reson. 2001;153(2):155–177. doi:10.1006/jmre.2001.2340 [doi]
9. Parkinson B, Bouloukakis K, Weijers HW, Olatunji J, Szmigiel M, Hunter MW, Froelich T, Bailey J, Garwood M. Design and manufacture of an ultra-compact, 1.5 T class, controlled-contact resistance, REBCO, brain imaging MRI magnet. Supercond Sci Technol. 2024;37:115026. doi:10.1088/1361-6668/ad80d5. [doi]
10. Theilenberg S, Shang Y, Ghazouani J, Kumaragamage C, Nixon TW, McIntyre S, Vaughan JT, Parkinson B, Garwood M, de Graaf RA, Juchem C. Design and realization of a multi-coil array for B0 field control in a compact 1.5T head-only MRI scanner. Magn Reson Med. 2023 Sep;90(3):1228-1241. doi: 10.1002/mrm.29692. [doi]
11. Martins MJ, Vidoto ELG, Tannús A. inventors; Universidade de São Paulo, assignee. Espectrômetro para uso em sistemas de ressonância magnética e sistemas de ressonância magnética. Patent No. BR102015000624-1. 2015.
12. Pizetta DC. PyMR: A Framework for Programming Magnetic Resonance Systems. PhD thesis. Instituto de Física de São Carlos; 2018. DOI: 10.11606/T.76.2019.tde-06052019-103714. [doi]
13. Theilenberg S, et al. Dynamic B_0 shimming using multi-coil arrays in low-field MRI. Magn Reson Med. 2024;92(1):211–224. doi:10.1002/mrm.30105 [doi]

Cite this abstract