Berk Silemek, Nur Izzati Huda Zulkarnain-Lemke1, Yigitcan Eryaman 2
1Center for Magnetic Resonance Research, Minneapolis, United States of America
2Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, United States of America
Presenting Author: Yigitcan Eryaman
Synopsis
Motivation:
Goals:
Approach:
Hypothesis:
Full abstract & presentation
The full text, figures, and any recorded presentation for this abstract are not shown here. Log in if you are a member or registered attendee with access.
Full abstracts, figures, and presentations for Cape Town - 2026 ISMRM-ISMRT Annual Meeting and Exhibition are available to registered attendees. This content becomes freely available to the public roughly two years after the meeting.
To request or purchase access, contact the ISMRM Central Office at info@ismrm.org.
1. Eryaman Y, Turk EA, Oto C, Algin O, Atalar E. Reduction of the radiofrequency heating of metallic devices using a dual-drive birdcage coil. Magn Reson Med. 2013;69(3):845-852. doi:10.1002/mrm.24316 [doi]
2. Eryaman Y, Akin B, Atalar E. Reduction of implant RF heating through modification of transmit coil electric field. Magn Reson Med. 2011;65(5):1305-1313. doi:10.1002/mrm.22724 [doi]
3. Eryaman Y, Kobayashi N, Moen S, et al. A simple geometric analysis method for measuring and mitigating RF induced currents on Deep Brain Stimulation leads by multichannel transmission/reception. NeuroImage. 2019;184:658-668. doi:10.1016/J.NEUROIMAGE.2018.09.072 [doi]
4. Sadeghi-Tarakameh A, Zulkarnain NIH, He X, Atalar E, Harel N, Eryaman Y. A workflow for predicting temperature increase at the electrical contacts of deep brain stimulation electrodes undergoing MRI. Magn Reson Med. 2022;88(6):2311-2325. doi:10.1002/mrm.29375 [doi]
5. Zulkarnain NIH, Sadeghi-Tarakameh A, Thotland J, Harel N, Eryaman Y. A workflow for predicting radiofrequency-induced heating around bilateral deep brain stimulation electrodes in MRI. Med Phys. 2024;51(2):1007-1018. doi:10.1002/mp.16913 [doi]
6. Silemek B, Acikel V, Oto C, et al. A temperature sensor implant for active implantable medical devices for in vivo subacute heating tests under MRI. Magn Reson Med. 2018;79(5):2824-2832. doi:10.1002/mrm.26914 [doi]
7. Acikel V, Silemek B, Atalar E. Wireless control of induced radiofrequency currents in active implantable medical devices during MRI. Magn Reson Med. 2020;83(6):2370-2381. doi:10.1002/mrm.28089 [doi]
8. Silemek B, Seifert F, Petzold J, Brühl R, Ittermann B, Winter L. Wirelessly interfacing sensor-equipped implants and MR scanners for improved safety and imaging. Magn Reson Med. 2023;90(6):2608-2626. doi:10.1002/mrm.29818 [doi]
9. Silemek B, Seifert F, Petzold J, et al. Rapid safety assessment and mitigation of radiofrequency induced implant heating using small root mean square sensors and the sensor matrix Qs. Magn Reson Med. 2022;87(1):509-527. doi:10.1002/mrm.28968 [doi]
10. Winter L, Silemek B, Petzold J, et al. Parallel transmission medical implant safety testbed: Real-time mitigation of RF induced tip heating using time-domain E-field sensors. Magn Reson Med. 2020;84(6):3468-3484. doi:https://doi.org/10.1002/mrm.28379 [doi]
11. Etezadi-Amoli M, Stang P, Kerr A, Pauly J, Scott G. Controlling radiofrequency-induced currents in guidewires using parallel transmit. Magn Reson Med. 2015;74(6):1790-1802. doi:10.1002/mrm.25543 [doi]
12. Godinez F, Scott G, Padormo F, Hajnal JV, Malik SJ. Safe guidewire visualization using the modes of a PTx transmit array MR system. Magn Reson Med. 2020;83(6):2343-2355. doi:10.1002/mrm.28069 [doi]
13. Silemek B, Seifert F, Brühl R, Ittermann B, Winter L. Impedance measurements detect the temperature rise near DBS. In: Proc. Intl. Soc. Mag. Reson. Med. Vol 33. 2025:0179.
14. Silemek B, Yalaz M, Seifert F, et al. Built-in RF safety for active implants: Harnessing impedance measurements from a commercial deep brain stimulator. In: Proc. Intl. Soc. Mag. Reson. Med. Vol 32. 2024:0786.
15. Macchi EG, Gallati M, Braschi G, Persi E. Dielectric properties of RF heated ex vivo porcine liver tissue at 480 kHz: measurements and simulations. J Phys Appl Phys. 2014;47(48):485401. doi:10.1088/0022-3727/47/48/485401 [doi]
16. Busch C, Rupitsch SJ, Moeller K. Influence of temperature-dependent tissue parameters on monopolar coagulation model. Curr Dir Biomed Eng. 2022;8(2):466-469. doi:10.1515/cdbme-2022-1119 [doi]
17. Nakagawa H, Yamanashi WS, Pitha JV, et al. Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With a Saline-Irrigated Electrode Versus Temperature Control in a Canine Thigh Muscle Preparation. Circulation. 1995;91(8):2264-2273. doi:10.1161/01.CIR.91.8.2264 [doi]
18. Leung TKW, Ji X, Peng B, et al. Micro-electrodes for in situ temperature and bio-impedance measurement. Nano Sel. 2021;2(10):1986-1996. doi:10.1002/nano.202100041 [doi]
19. Sulkin MS, Laughner JI, Hilbert S, et al. Novel Measure of Local Impedance Predicts Catheter–Tissue Contact and Lesion Formation. Circ Arrhythm Electrophysiol. 2018;11(4):e005831. doi:10.1161/CIRCEP.117.005831 [doi]
20. Pesch E, Riesinger L, Vonderlin N, et al. Role of catheter location on local impedance measurements and clinical outcome with the new direct sense technology in cardiac ablation procedures. IJC Heart Vasc. 2022;42:101109. doi:10.1016/j.ijcha.2022.101109 [doi]
21. Owen SF, Liu MH, Kreitzer AC. Thermal constraints on in vivo optogenetic manipulations. Nat Neurosci. 2019;22(7):1061-1065. doi:10.1038/s41593-019-0422-3 [doi]
22. Zulkarnain NIH, Sadeghi-Tarakameh A, Lagore RL, et al. Feasibility of using toroidal transceivers for acquiring intraoperative MR images around deep brain stimulation electrodes. NeuroImage. 2024;302:120912. doi:10.1016/j.neuroimage.2024.120912 [doi]
23. Butson CR, Maks CB, McIntyre CC. Sources and effects of electrode impedance during deep brain stimulation. Clin Neurophysiol. 2006;117(2):447-454. doi:10.1016/j.clinph.2005.10.007 [doi]
24. Geselowitz DB. An application of electrocardiographic lead theory to impedance plethysmography. IEEE Trans Biomed Eng. 1971;18(1):38-41. doi:10.1109/TBME.1971.4502787 [doi]
25. Larson ER, Feldman MD, Valvano JW, Pearce JA. Analysis of the spatial sensitivity of conductance/admittance catheter ventricular volume estimation. IEEE Trans Biomed Eng. 2013;60(8):2316-2324. doi:10.1109/TBME.2013.2256134 [doi]
26. Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996;41(11):2251-2269. doi:10.1088/0031-9155/41/11/002 [doi]
27. Gabriel C, Peyman A, Grant EH. Electrical conductivity of tissue at frequencies below 1 MHz. Phys Med Biol. 2009;54(16):4863-4878. doi:10.1088/0031-9155/54/16/002 [doi]
28. Latikka J, Kuurne T, Eskola H. Conductivity of living intracranial tissues. Phys Med Biol. 2001;46(6):1611-1616. doi:10.1088/0031-9155/46/6/302 [doi]
29. Baumann SB, Wozny DR, Kelly SK, Meno FM. The electrical conductivity of human cerebrospinal fluid at body temperature. IEEE Trans Biomed Eng. 1997;44(3):220-223. doi:10.1109/10.554770 [doi]
30. Dipa SA, Pramanik MM, Rabbani M, Kadir MA. Effects of temperature on electrical impedance of biological tissues: ex-vivo measurements. J Electr Bioimpedance. 2024;15(1):116-124. doi:10.2478/joeb-2024-0013 [doi]
31. Rossmann C, Haemmerich D. Review of temperature dependence of thermal properties, dielectric properties, and perfusion of biological tissues at hyperthermic and ablation temperatures. Crit Rev Biomed Eng. 2014;42(6):467-492. doi:10.1615/CritRevBiomedEng.2015012486 [doi]
32. Hasgall PA, Di Gennaro F, Baumgartner C, Neufeld E, Lloyd B, Gosselin MC, Payne D, Klingenböck A, Kuster N. IT'IS Database for thermal and electromagnetic parameters of biological tissues. Version 4.1. IT'IS Foundation; 2022. doi:10.13099/VIP21000-04-1 [doi]
33. Tian Y, Wang J, Jiang L, et al. The need to be alert to complications of peri-lead cerebral edema caused by deep brain stimulation implantation: a systematic literature review and meta-analysis study. CNS Neurosci Ther. 2022;28(3):332-342. doi:10.1111/cns.13802 [doi]
34. Silemek B, Seifert F, Yalaz M, et al. Read My Leads: Subject-Specific RF Hazard Assessment and Mitigation for DBS Implants in MRI. Magn Reson Med. 2026;95(4):2316-2330. doi:10.1002/mrm.70186 [doi]
35. Eleopra R, Rinaldo S, Devigili G, et al. Brain impedance variation of directional leads implanted in subthalamic nuclei of Parkinsonian patients. Clin Neurophysiol. 2019;130(9):1562-1569. doi:10.1016/j.clinph.2019.06.001 [doi]
36. Lempka SF, Miocinovic S, Johnson MD, Vitek JL, McIntyre CC. In vivo impedance spectroscopy of deep brain stimulation electrodes. J Neural Eng. 2009;6(4):046001. doi:10.1088/1741-2560/6/4/046001 [doi]